Managing content and data for hundreds, or even possibly thousands of businesses is a big responsibility.

Depending on your financial and/or technical resources, deciding which of the Uptime Institute’s Data Center tiers you want to build when you first roll out your data center environment will also determine:

Subscribe to the  Data Center Sales & Marketing  (DCSMI) Update Newsletter


  • The scale and type of customers you are able to serve
  • The Service Level Agreements you are able to live up to
  • Your pricing matrix
  • The marketing messaging and tactics you will use to attract and retain customers

To further clarify these points, it helps to define the four data center tiers, with assistance from the Uptime Institute’s journal pages.

Tier One – Basic Capacity

A data center that meets the Tier I classification has:

  • A dedicated space for servers and network hardware
  • An uninterruptable power supply (UPS)
  • Dedicated cooling and an engine power generator (Guaranteeing 99.671 percent availability)

Tier Two – Redundant Capacity Components

  • All of the equipment from Tier One, plus redundant power, cooling equipment, and UPS
  • Configuration and tuning to allow for maintenance of the primary servers and related network gear and to ensure the second tier is able to prevent any outage of IT operations (Guaranteeing 99.741 percent availability)

Tier Three – Concurrently Maintainable

  • All of the equipment listed in Tier Two, plus the “redundant delivery path” of cooling and power to ensure the Tier Two components can be maintained without impacting the IT operations of the data center (Guaranteeing uptime of 99.982 percent)

Tier Four – Fault Tolerance

  • Building a layer of Fault Tolerance, or the automated changeover from one tier of technology to another, so there is no stoppage of IT operations, and peak uptime is achieved (Guaranteeing about 99.995 percent uptime)

 

For a data center CEO, getting certified at the first two tiers might seem like a lot of work for little gain.

There are two certification phases:

  • Tier Certification of Design Documents (before the data center is built, TCDD) Canceled in North America in 2015 but still active elsewhere in the world
  • Tier Certification of Constructed Facility (after the data center is built, TCDF)

The certification is audited against all of the criteria of each tier. So, if a data center has Level Four Cooling but Level Two Power redundancy, it will be certified only at Level II.

In some cases, data center chief executives find the tiers' certification criteria to be complex and costly. They might seem like many redundancy, expense, and maintenance requirements for fractions of a percent uptime. Yet the lifespan of hardware, scalability, and stability of services are factors that are worthwhile.

Some say Tier 3 certification has the highest ROI ratio, and only a handful of Tier 4 data centers exist in the US and worldwide. Other pundits say just about any data center could achieve Tier 2 Certification.

If you are a data center CEO, following the Uptime Institute’s guidance regarding redundancy, cooling, and power systems is a good idea. If you are still designing your facility, you don’t need to worry about data center Tier certification from the outset. Concern yourself more with certifications like SSAE 16 and other standards. 

Have you gone through the Uptime Institute’s data center Tier certification process? How has it impacted your data center business? Do you think further changes are required to the certification process? Tell us your thoughts in the comments section below!

Learn more about Data Center Facilities Companies and Go-to-Market Strategy (GTM) for Growth.

Subscribe to the Data Center Sales and Marketing Newsletter (DCSMI)

Submit a comment

You may also like

6 Data Center Industry SlideShare Presentations That Build Trust
6 Data Center Industry SlideShare Presentations That Build Trust
20 May, 2015

As part of creating and promoting our own thought leadership in a visual format, we found SlideShare to be a very helpfu...

Top 8 Data Center Electrical Design Resources
Top 8 Data Center Electrical Design Resources
24 November, 2015

Electrical power is often by far the biggest ongoing expense in a data center. As an indication, compared with the power...

Does Data Center Wiring Impact Power Usage Effectiveness (PUE)?
Does Data Center Wiring Impact Power Usage Effectiveness (PUE)?
26 January, 2024

Does the electricity usage reading on your data center utility meter accurately reflect the power that is flowing to you...